Chapter 2 - Features and Operation

Automatic Call Back Timer

Description
The Automatic Call Back Timer invokes a call back anytime a user listens to a busy tone for a
programmable period of time. The Automatic Call Back Timer can be set to 00-99 seconds.
A value of 00 disables the timer. An Automatic Call Back does not occur when the timer is
disabled.
Programming Steps
1. Press the AUTO CALL BACK TIMER flexible button (FLASH 01, Button #17). The following
message displays:
2. Enter a valid number on the dial pad that corresponds to 00-99 seconds in 1-second
increments.
3. Press HOLD to save the entry. A confirmation tone sounds and the display updates.
DEFAULT ... Automatic Call Back Timer is set for 03 seconds (enabled).

Auto Callback - DSS / BLF

Description
The Auto Callback DSS/BLF flash rate is the rate at which a DSS button of a station returning
your call back flashes. This flash rate can be programmed to 29 different options identified in
the flash rate table. This enables the programmer to customize the key system configuration
to desired flash rates.
Programming Steps
1. Press the AUTO CBCK – DSS/BLF flexible button (FLASH 07, Button #7). The following
message displays:
2. Enter a valid number (00-28) on the dial pad to correspond to one of the 29 available
options. (Refer to
3. Press HOLD to save the entry. A confirmation tone sounds and the display updates.
DEFAULT ... Auto Callback DSS/BLF flash rate is set for a Red 120 ipm Flash (10).
AU TO C A LL B ACK
03
AU TO C B CK DS S / B LF
RE D 1 2 0 I PM F LA S H
Table 2-11 on page
00-99
00-28
2-130.)