Chapter 2 - Features and Operation

Guard Timer

Description
The outgoing Guard Timer is used to set the length of time a CO is held busy to outgoing
seizure after a valid release is detected. If a user attempts to access a CO line before the Guard
Timer expires, their LED illuminates to indicate that the line is seized, however the CO line is
not actually seized until the timer expires. The user gets a busy tone, and may receive a
delayed CO dial tone if the timer is set to a large value.
Programming Steps
1. Press the GUARD TIMER button (FLASH 40, Page C, Button #4) in the flexible button
field. The following message displays:
2. Enter a valid number on the dial pad which corresponds to 1–60 (100 ms to 6 seconds).
3. Press HOLD to save the entry. A confirmation tone sounds and the display updates.
DEFAULT ...Guard Timer is set for .5 seconds.

Transmit Volume

Description
Up to ten volume levels are available for each CO Line in the system.
Programming Steps
1. Press FLASH and dial [40]. The following message displays:
2. Enter a valid number for the range of lines being programmed. If only one line is being
programmed, enter that number twice (001 001).
3. Press HOLD to save the entry. A confirmation tone sounds and the display updates.
Flexible Button #19 (Page A) is lit.
G UA R D T IM E R
0 5
Do NOT adjust this option without consulting Technical Support first. The default
settings were set to apply to most applications. Have the dB readings on all CO lines
available when calling Technical Support.
CO LI N E AT TR I B U TE S
S E LE C T A CO L IN E R A NG E
If HOLD is pressed without entering a CO range, ALL CO lines are selected.