Setting
Receiving
-
Buffer
NetWare, IPP,
USB and Port
9100
EtherTalk
Compat
LPD Spool,
SMB Spool
IPP Spool
Sets the memory of the receiving buffer (temporary storage location for
data arriving from the computer) for each interface. Set the spooling
setting, allocation location, and size of memory for each of the LPD, SMB
and IPP interfaces.
The receiving buffer size can be changed according to operating status
and purpose. Increasing the receiving buffer size sometimes frees up the
computer supporting a particular interface more quickly. The maximum
size that can be set changes according to the amount of free memory.
Note
• When a port is disabled, its corresponding items are not displayed.
• Even if the receiving buffer size is increased, the time required to free up
a computer sometimes does not change depending on the size of data
arriving from the computer.
Specify memory size from 64 to 1024 KB in 32 KB increments. The default
memory size is [64K] for USB. Otherwise, it is [256K].
Note
• [IPP] appears when the HDD Extension Kit (optional) is not installed. [IPP
Spool] is displayed when the hard disk is installed.
Specify memory size from 1024 to 2048 KB in 32 KB increments. The
default is [1024K].
• [No Spooling] (default)
Spooling is not performed. Data cannot be simultaneously printed and
received using the LPD or SMB interfaces.
When printing on the LPD interface, set the memory size of the receiving
buffer exclusively for LPD from 1024 to 2048 KB in 32 KB increments.
The default is [1024K].
When printing on the SMB interface, set the memory size of the
receiving buffer exclusively for SMB from 64 to 1024 KB in 32 KB
increments. The default is [256K].
• [Hard Disk]
Spooling to the hard disk is performed. The hard disk is used as the
receiving buffer for spooling. This item appears only when HDD
Extension Kit (optional) is installed.
• [Memory]
Spooling to memory is performed. Memory is used as the receiving
buffer for spooling. When this optional value is selected, set the memory
size of the receiving buffer for spooling from 0.5 to 32.00 MB in 0.25 MB
increments. The default is [1.00M]. Note that print data exceeding the
preset memory size cannot be received to memory. In this case, select
[Hard Disk] or [No Spooling].
Important
• When the LPR byte count is disabled and a document larger than the size
set as the spooling memory is received, the job is repeatedly transmitted.
If this happens, either open the [Ports] tab in the print driver Properties
dialog box, and enable the LPR byte count, or change the size of spooling
memory so that it is larger than the size of the document.
• [No Spooling] (default)
Spooling is not performed. Data cannot be simultaneously printed and
received using the IPP interface. Set the memory size of the receiving
buffer exclusively for IPP from 64 to 1024 KB in 32 KB increments. The
default is [256K].
• [Hard Disk]
Spooling to the hard disk is performed. The hard disk is used as the
receiving buffer for spooling.
Note
• [IPP Spool] appears only when HDD Extension Kit (optional) is installed.
[IPP] is displayed when HDD Extension Kit is not installed.
Description
5.2 Common Menus Setting
195

Advertisement

Table of Contents
loading

Table of Contents