Omron LD-60 User Manual page 85

Hide thumbs Also See for LD-60:
Table of Contents

Advertisement

Callout
A
Standard Equipment
B
User-Supplied Equipment
C
Wiring Terminal Block
D
Typical User Loads
Analog I/O
Connector type
The 0-10 V analog inputs have an input impedance of about 35 kΩ.
l
The 0-30 V analog inputs have an input impedance of about 110 kΩ.
l
The analog outputs have an output impedance of about 200 Ω.
l
The maximum output current of each analog output is 10 mA. Exceeding the maximum
output current will result in damage to the analog output module.
Aux Sensors
Connector type
Use
11970-000 Rev M
Description
HDB15M
Pin No.
Designation
1
ANALOG_IN1
2
ANALOG_IN2
3
ANALOG_IN3
4
ANALOG_IN4
5
ANALOG_IN5
6
ANALOG_IN6
7
ANALOG_IN7
8
ANALOG_IN8
9
ANALOG_OUT1 0 – 20 V Range
10
ANALOG_OUT2 0 – 20 V Range
11
ANALOG_OUT3 0 – 20 V Range
12
ANALOG_OUT4 0 – 20 V Range
13, 14, 15 GND
HDB15M
Low Front Laser, optional Side Lasers
LD-60/90 Platform User's Manual
Callout
Description
E
Load
F
Outputs 1-16
G
Equivalent Circuit
Notes
0 – 10 V Range
0 – 10 V Range
0 – 10 V Range
0 – 10 V Range
0 – 30 V Range
0 – 30 V Range
0 – 30 V Range
0 – 30 V Range
Chapter 6: Connectivity