3.8  Installing the Docking Station
3. Lower the docking station down, so the two bolts on the back of the docking station
slide into the bracket, to secure the docking station to the wall.
Floor-mount, without Floor Plate
Screw the base of the docking station directly to the floor, using three user-supplied screws. For
dimensions of the available holes in the base, refer to Figure 3-20. We recommend M5 self-
tapping screws for this.
Floor-mount, with Floor Plate
This mounting method uses the floor plate. The floor plate is not shipped attached to the dock-
ing station, so you must attach it for this type of mount. It will be in the crate with the plat-
form, right behind the docking station.
Attaching the Floor Plate
Refer to the following figures.
1. Tip the docking station onto its back, so you can access the underside.
2. Remove the two lowest screws (M4 x 12 flat-head), if present.
In the following figure, these screws are circled. The location of the third screw hole is
also circled.
3. Attach the floor plate to the base of the docking station with three M4 x 12 flat-head
stainless steel screws.
The floor plate comes with three screws, so you will have two spares.
The docking station and floor plate do not need to be attached to the floor, as the weight of the
AMR on the floor plate will keep the docking station from moving.