8.7  Replacing Non-Periodic Parts
1. Remove the M10 x 30 mm screw holding the caster to the platform.
The screw was installed with Loctite 263.
Retain the screw for attaching the new caster.
Callout
A
B
C
D
E
2. Remove the caster from the platform.
3. Put the new caster in place, and attach with the M10 x 30 mm screw you removed from
the old caster.
Use Loctite 263.
Torque to 27 N·m (20 ft·lb
If you removed the battery for this procedure:
1. Return the platform to its upright position.
2. Reinstall the battery, connect the power and data cables, and close the battery com-
partment door.
3. Reinstall the battery door skin.
4. Reinstall the side skins.
146
Figure 8-17. Platform Caster Replacement
(4) M6 x 22 Screw, Flat Head Socket
Caster, Heavy Duty, with Bolt Hole Fitting
M10 x 30 mm Screw, Flat Head Socket
Use Locktite 263 on the M10 x 30 Screw
Completed Assembly
).
f