NEC ZA-SA3500G Function Manual page 339

Hide thumbs Also See for ZA-SA3500G:
Table of Contents

Advertisement

Secondary SSID
Common Setting
Host IP Address
The maximum number of files acquired for each interface is twelve. The size per file is 10 Mbytes. Since this product
can store up to 120 Mbytes in memory, it must be set not to exceed the limit.
For example, if all four interfaces need to be captured, check the four interfaces and specify the number of each file as
3.
(4 interfaces x 3 files x 10 Mbytes = 120 Mbytes)
To collect only LAN and WAN, check the LAN and WAN and set the number of each file to 6, 60 MB of each capture
can be collected.
[Caution]
・When the wireless LAN function is disabled, capture is not performed even if primary SSID and secondary SSID are
checked.
・Capture data is overwritten and saved from old data. Be careful when there is traffic that exceeds the maximum
capacity set between the start and stop.
Checked: Collect secondary SSID
packet dumps
Unchecked: Do not collect
secondary SSID packet dumps
Specify the destination host and source
host of the packet. Select "any" to
target all IP addresses.
Select the number of files to save
by using the pulldown menu.
|Device Information Confirmation
Disabled,
Number of
files 3
any
339