Add Pvc Destination - 3Com CoreBuilder 7000 Management Manual

Atm switches
Hide thumbs Also See for CoreBuilder 7000:
Table of Contents

Advertisement

C
7: C
184
HAPTER
ONFIGURING

Add PVC Destination

V
C
IRTUAL
HANNELS
Creates an additional destination connection (branch) for an existing
point-to-multipoint PVC. Enter the call ID of the original PVC setup and
the parameters: output port number, VPI/VCI and CLP, with the same
permissible values. Default values for cell loss level, priority, and cell loss
priority are used (see Table 28). The full PVC call setup limits apply.
You cannot add an additional PVC destination to a P2P PVC.
Command Actions
Enter the menu sequence: (3) CON: Connections
Enter a parameter at the prompt
Parameter
Call ID
Output port ID
Output port VPI
Output port VCI
Output port CLP
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
3 4 1 3 9 5.4 0 55 0
The following message is displayed:
A new output VC was created with call id:
(4) S&C: Setup and Config Conns
(1) PVC: PVC operations
(3) CRO: Create out VC in call
Format or Range
Integer
slot.port
See (3)CON\(4)S&C\(1)PVC for VPI/VCI limits
See (3)CON\(4)S&C\(1)PVC for VPI/VCI limits
0 for clear
1 for set
2 for no change
3 4 1 3 [parameters]
An additional PVC destination with parameters
specified is created.
A new output VC was created
with call id:
out connection id:
out connection id:
1
3
9
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Corebuilder 7000 series

Table of Contents