MPOA Server Configuration Parameters
.
Table 39 MPOA Server Configuration Parameters
Name
keep-alive time
keep-alive lifetime
internetwork-layer protocols
MPS initial retry time
MPS retry time maximum
MPS give up time
default holding time
MPOA Devices Configuration
Description
The MPS must transmit MPOA keep-alives
every MPS-p1 seconds. Minimum=1 sec.,
default=10 sec., maximum=300 sec.
The length of time an MPC may consider a
keep-alive valid in seconds. Minimum=3 sec.,
default=35 sec., maximum=1000 sec.
The set of protocols for which MPOA
resolution is supported.
Initial retry time used by the MPOA retry
mechanism. Minimum=1 sec., default=5 sec.,
maximum=300 sec.
Maximum retry time used by the MPOA retry
mechanism. Minimum=10 sec., default=40
sec., maximum=300 sec.
Minimum time to wait before giving up on a
pending resolution request. Minimum=5 sec.,
default=40 sec., maximum=300 sec.
The default holding time used in NHRP
resolution replies. An egress MPS may use
local information to determine a more
appropriate holding time. Minimum=1 min.,
default=20 min., maximum=120 min.