3Com CoreBuilder 7000 Management Manual page 218

Atm switches
Hide thumbs Also See for CoreBuilder 7000:
Table of Contents

Advertisement

C
7: C
218
HAPTER
ONFIGURING
V
C
IRTUAL
HANNELS
SSCOP Configuration Parameters
Table 32 shows the SSCOP Configuration Parameters displayed by the
command.
.
Table 32 SSCOP Configuration Parameters
SSCOP
Parameter
Description
MaxCC
Maximum value for the state variable VT(CC), corresponding to
the maximum number of transmissions of a BGN, END, or RS
PDU.
MaxPD
Maximum acceptable value for the state variable VT(PD) before
sending a POLL PDU and resetting VT(PD) to zero.
MaxSTAT
Maximum number of list elements permissible in a STAT PDU.
Window
Sequence number of the first SD or SDP PDU not allowed by the
receiver.