Pentair FLECK 3150 NXT Installer Manual page 98

Hide thumbs Also See for FLECK 3150 NXT:
Table of Contents

Advertisement

Installer manual Fleck 3150 NXT/NXT2 - Programming
a) Edit assistance phone using
ð Assistance phone is empty by default;
ð Each character can be chose from 1 to 9 or stay
empty;
b) Press
next parameter.
6.2.5.7
System type
Select the system in which the valve(s) operate(s).
Options:
• 4: single valve;
• 5: multiple valves, parallel interlock system (2- 8 units);
• 6: multiple valves, parallel series regeneration system (2- 8 units);
• 7: duplex alternating immediate system (2 units);
• 8: duplex alternating delayed system (2 units);
• 9: multiple valves, parallel system with standby unit (2- 8 units);
• 14: multiple valves, system on-demand (2- 8 units).
a) Select the system type with
ð Default system: system 4;
b) Press
next parameter.
6.2.5.8
Number of tanks
Set the number of valves to be connected (2 to 8 valves) in the system.
Info
Only visible in multiple valve systems and only present on the master valve.
Options:
• 2 to 8 valves in the system.
a) Select number of tanks with
ð Default setting: 2 valves;
b) Press
next parameter.
98 / 182
to validate the selection and advance to the
to validate the selection and advance to the
to validate the selection and advance to the
,
and ;
and
;
and
;
Ref. MKT-IM-010 / C - 18.10.2019
Example: 4 Single valve.
Example: 5 multiple
valves.