Pentair FLECK 3150 NXT Installer Manual page 108

Hide thumbs Also See for FLECK 3150 NXT:
Table of Contents

Advertisement

Installer manual Fleck 3150 NXT/NXT2 - Programming
a) Enable lock window with
ð Default setting: off;
b) Press
next parameter.
c) Set lock start time with
d) Press
next parameter;
e) Set lock end time with
f) Press
next parameter.
6.2.5.25 Programming regeneration cycles time
Set the regeneration cycles duration in minutes.
Info
A maximum of 5 cycles can be programmed.
Info
For filter system only backwash and rapid rinse are available.
Info
The sequence of the regeneration cycles depends upon regenerant flow, see System
regeneration cycle [}Page 20].
108 / 182
and
to validate the selection and advance to the
and
to validate the selection and advance to the
and
to validate the selection and advance to the
;
;
;
Ref. MKT-IM-010 / C - 18.10.2019
Lock window #2
activated.
Lock window #2 starts at
13:00.
Lock window #2 ends at
14:00.