Parameter
CPO AUX
RELAY
VOLUME
CPO AUX
RELAY TIME
FLOW METER 1.0" PADDL
PEAK FLOW
RATE
ADD XXX
LITERS EVERY
YYY PULSES
6.1.5.2
Entering master programming mode
a) Press
enter the master programming mode.
6.1.5.3
Language setting
Select the displayed language.
Options:
• English;
• French;
• German;
• Italian;
• Spanish.
a) Select the language to be displayed with
b) Press
next parameter.
Ref. MKT-IM-010 / C - 18.10.2019
Installer manual Fleck 3150 NXT/NXT2 - Programming
Options
1 to 9'999
00:00:00
to 02:00:00
E
1.0" TURBI
NE
1.5" PADDL
E
1.5" TURBI
NE
2.0" PADDL
E
3.0" PADDL
E
GENERIC
20 to 2'000
1 to 255
XXX: number of liter
YYY: number of pulses
and
simultaneously for 5 seconds to
to validate the selection and advance to the
Definition
L
Activate the relay output during a
service based upon the volume of
treated water. Relay is activated
for a set time after every set
Hour
volume is treated. Not compatible
with aux. relay activation.
-
Default flow meter type is based
on the valve type.
-
This screen will only display on
the lead (#1) unit for system types
6 & 7.
-
All other system types it will
display for all units.
-
-
-
-
l/min
Only displayed if "Generic" is
chosen for the flow meter.
and
Note
.
67 / 182