Pentair FLECK 3150 NXT Installer Manual page 61

Hide thumbs Also See for FLECK 3150 NXT:
Table of Contents

Advertisement

6. Operating
mode
6.1.2
Commands
Info
At any time, press D to return to the home screen without saving.
Info
Menus are displayed in a defined and incremental order.
a) Press
b) Use
c) Use
d) Press D at any time to exit programming mode without saving.
6.1.3
Setting the time of the day
Set the time in the system.
Mandatory
In multiple valve systems, set the time of day on the lead valve (#1).
Info
The time of day will be automatically updated on the other valves in the system within
10 seconds.
Info
If, during time setting, no buttons are pushed for 5 seconds, the system leaves setting.
a) Press
b) Set the controller with
c) Press
service mode.
6.1.4
Basic programming
Info
Menus are displayed in a defined and incremental order.
Ref. MKT-IM-010 / C - 18.10.2019
Installer manual Fleck 3150 NXT/NXT2 - Programming
• remaining volume in volumetric mode;
• remaining days before regeneration in timeclock mode.
to pass to the next step.
to move the cursor to the next digit.
and to
adjust the values.
or
for 2 seconds.
,
to validate the selection and return to the
and
.
61 / 182

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fleck 3150 nxt2

Table of Contents