a) Set the trip point 2 flow rate with
ð Can be adjusted from trip point 1+1 to 3998 l/min.
b) Press
next parameter.
c) Set the trip point 2 delay with
ð Can be adjusted from 30 to 99 seconds.
d) Press
next parameter.
Trip point 3
Info
Only visible if controller programmed as valve position #1 and system size to 4.
a) Set the trip point 3 flow rate with
ð Can be adjusted from trip point 2+1 to 3999 l/min.
b) Press
next parameter.
c) Set the trip point 3 delay with
ð Can be adjusted from 30 to 99 seconds.
d) Press
next parameter.
6.1.5.16 Regeneration days override
Set the maximum number of days that the valve is in service without regenerating,
regardless from the volume of water used.
Info
For a timeclock valve, this value must be set as regeneration period in days. For
metered valves, it is regenerated once the amount of days is reached at a preset time
unless the meter triggers regeneration before. Calendar override initiate regeneration
only if no regeneration has been initiated within the delay programmed in calendar
override parameter.
a) Adjust the number of days with
b) Press
next parameter.
ð Can be adjusted from:
1 to 99 days for timeclock regeneration;
OFF to 99 days for metered regeneration.
Ref. MKT-IM-010 / C - 18.10.2019
Installer manual Fleck 3150 NXT/NXT2 - Programming
to validate the selection and advance to the
to validate the selection and advance to the
to validate the selection and advance to the
to validate the selection and advance to the
to validate the selection and advance to the
,
and
.
,
and
.
,
and
.
,
and
.
,
and
.
Without calendar forcing.
Forcing every 3 days.