Installer manual Fleck 3150 NXT/NXT2 - Programming
Parameter
TRIP POINT 2
TRIP DELAY 2
TRIP POINT 3
TRIP DELAY 3
REGENERATIO
N DAY
OVERRIDE
REGENERATIO
N TIME
CYCLE 1
CYCLE 2
CYCLE 3
CYCLE 4
CYCLE 5
AUXILIARY
RELAY
AUX RELAY
OUTPUT
START
AUX RELAY
OUTPUT END
CHEMICAL
PUMP
66 / 182
Options
Definition
1 to 3997
30 to 99
Second
(30 seconds default)
1 to 3997
30 to 99
Second
(30 seconds default)
OFF to 99
00:00:00
Hour
to 23:59:59
OFF to
04:00:00
OFF
to 04:00:00
OFF
to 04:00:00
OFF
to 04:00:00
OFF
to 04:00:00
Enabled
Disabled
(Default)
00:00:00
Hour
to 18:00:00
00:00:00
to 18:00:00
Enabled
Disabled
(Default)
L/m
This screen will only display for
system 14 and will only appear
with the system sized to 3 or 4 on
the master controller (Valve
address #1).
Use the SHIFT button to move to
the left.
L/m
This screen will only display for
system 14 and will only appear
with the system sized to 4 on the
master controller (Valve
address #1).
Use the SHIFT button to move to
the left.
Day
Days between regenerations for
timeclock mode.
Regeneration time will not appear
unless regeneration day override
or timeclock is on.
This screen will only display when
cycle 4 is not OFF.
-
Not compatible with CPO AUX
activation.
Only displayed if auxiliary relay is
enabled in previous screen.
Auxiliary relay will only display if
chemical pump is OFF for system
types 6 & 7.
-
This screen will only display on
the lead (#1) unit for system
types 6 & 7.
For all other system types, it will
display for all units.
Ref. MKT-IM-010 / C - 18.10.2019
Note