Pentair FLECK 3150 NXT Installer Manual page 88

Hide thumbs Also See for FLECK 3150 NXT:
Table of Contents

Advertisement

Installer manual Fleck 3150 NXT/NXT2 - Programming
Parameter
LANGUAGE
ASSISTANCE
NAME 1
ASSISTANCE
NAME 2
ASSISTANCE
PHONE
SYSTEM TYPE
NUMBER OF
TANKS
TRIP
POINT #X - LPM
TRIP
POINT #X -
SERVICE
DURATION
TRIP
POINT #X -
STANDBY
DURATION
88 / 182
Options
Definition
ENGLISH
English (default)
FRANCAIS
French
DEUTSCH
German
ITALIANO
Italian
ESPANOL
Spanish
NEDERLAN
Dutch
DS
PORTUGUE
Portuguese
S
4
Single unit (default) 1 unit.
5
Parallel interlock
6
Parallel series
regeneration
7
Alternating
immediate
8
Alternating delayed
9
Parallel with standby
14
On-demand
2 to 8
Valves in the system This screen will not be displayed
1 to 7563
l/min
1 to 90
Second
60 to 300
Second
-
12 characters maximum.
-
-
14 characters maximum.
2 to 8 units.
2 units.
2 to 8 units.
unit
for system type 4, 7 and 8.
System 14 only.
System 14 only;
Duration for which the service
flow rate must be greater than
the above trip point flow rate to
cause the next tank to move into
service position.
System 14 only;
Duration for which the service
flow rate must become lower
than the above trip point flow
rate to cause one of the tank of
the system to move back into
stand-by position.
Ref. MKT-IM-010 / C - 18.10.2019