Installer manual Fleck 3150 NXT/NXT2 - Programming
a) Set the safety coefficient with
ð Can be adjusted from 0 to 50%.
b) Press
next parameter.
6.1.5.14 Inlet water hardness
Set the inlet water hardness in the unit set on chapter Units [}Page 101]
a) Set the inlet water hardness with
b) Press
next parameter.
6.1.5.15 Trip points setting
Set the flow rate and switching delay when another tank is switched to service.
Info
Only visible in system 14.
Trip point 1
Info
Only visible if controller programmed as valve position #1.
a) Set the trip point 1 flow rate with
ð Can be adjusted from 0 to 3997 l/min.
b) Press
next parameter.
c) Set the trip point 1 delay with
ð Can be adjusted from 30 to 99 seconds.
d) Press
next parameter.
Trip point 2
Info
Only visible if controller programmed as valve position #1 and system size to 3 or 4.
72 / 182
to validate the selection and advance to the
to validate the selection and advance to the
to validate the selection and advance to the
to validate the selection and advance to the
,
and
.
,
and
.
,
and
.
,
and
.
Ref. MKT-IM-010 / C - 18.10.2019
No safety factor