9.4.11
Valve on tank assembly
a) Lubricate the Oring with approved silicone grease.
b) Spin the valve (1) onto the tank (2), ensuring the threads are not cross-threaded.
c) Rotate the valve (1) clockwise and freely, without using force until it comes to a
stop.
Info
This stop position is considered point zero.
d) Rotate the valve (1) clockwise from point zero to between ¼ turn and ½ turn.
CAUTION
Do NOT exceed 27 Nm of torque when installing the valve. Exceeding this limit may
damage the threads and cause failure.
Point 0
Ref. MKT-IM-010 / C - 18.10.2019
Installer manual Fleck 3150 NXT/NXT2 - Maintenance
¼ turn
Point 0
½ turn
151 / 182