Installer manual Fleck 3150 NXT/NXT2 - Programming
Chemical pump
Activate the relay output during the service based upon the volume of treated water.
Info
Only visible in metered systems.
Info
This parameter has two steps. The first one determines the volume which activates the
relay. The second one determines how long the relay has to be activated once the
volume has passed.
a) Activate the relay with
b) Default setting: disabled.
c) Press
next parameter.
d) Set the relay activating time with
e) Press
next parameter.
f) Set the relay deactivating time with
g) Press
next parameter.
6.1.5.20 Flow meter selection
Select the size of the flow meter.
Options:
• 1.0" paddle (standard for 2750 valve series);
• 1.0" turbine;
• 1.5" paddle (standard for 2815 and 2850 valve series);
• 1.5" turbine:
• 2.0" paddle (standard for 2900 and 3150 valve series);
• 3.0" paddle (standard for 3900 valve series);
• generic meter.
a) Select the flow meter with
b) Press
next parameter.
76 / 182
and
to validate the selection and advance to the
to validate the selection and advance to the
to validate the selection and advance to the
to validate the selection and advance to the
.
,
and
.
,
and
and
.
Ref. MKT-IM-010 / C - 18.10.2019
Disabled.
Relay enabled every
20 liter.
Relay enabled for 1 min.
.