Installer manual Fleck 3150 NXT/NXT2 - Installation
Side mounted configuration example
Upper distributor
A-2742-FU
Side mounted
adapter 18023
Tank
C-4278-F7
Upper distributor
A-2742-FL
5.7
System types
Info
For all multiple tank systems #5 and #6, NBP version valves must be used.
For all multiple tank systems #7, #8 (for NXT2 only), #9 and #14, WBP version valves
must be used in combination with solenoid valve in the outlet.
The solenoid valve needs to be connected to (P6 (for NXT) and P18 (for NXT2) OUTPUT –
24 VAC 50/60Hz, 0.25 A, MAX )
Info
In this chapter, systems up to four valves are used to describe and illustrate the
different multiple valves systems, even if the described system may control more than
four valves.
Metered immediate:
The controller monitors the volume of water used. As soon as the capacity is
exhausted, the controller starts the regeneration process.
Metered delayed:
The controller monitors the volume of water used. When the remaining capacity is less
than the programmed reserve, the controller queues a regeneration that will start at
the programmed regeneration time.
Time clock:
The controller initiates the regeneration at regular preset time interval at the
programmed regeneration time.
44 / 182
Valve 3150 NXT
SBV 28182
Air check 18979
Ref. MKT-IM-010 / C - 18.10.2019