Installer manual Fleck 3150 NXT/NXT2 - Programming
6.1.5.4
System type
Select the system in which the valve(s) operate(s).
Options:
• 4: single valve;
• 5: multiple valves, parallel interlock system;
• 6: multiple valves, parallel series regeneration system;
• 7: duplex alternating immediate system;
• 9: multiple valves, parallel system with standby unit;
• 14: multiple valves, system on-demand.
a) Set the system type with
b) Press
next parameter.
6.1.5.5
Valve address in the system
Set the valve position in the system.
Info
Only visible in systems 5, 6, 7, 9 and 14.
Info
The number #1 is the lead valve (master) and contains the programmed parameters
used by the other controllers in the system in order to control the regeneration and
service or standby positions.
Options:
• address #1: valve 1, lead (master);
• address #2: valve 2;
• address #3: valve 3;
• address #4: valve 4.
68 / 182
and
to validate the selection and advance to the
.
Example: 4 Single valve.
Example: 5 multiple
valves.
Ref. MKT-IM-010 / C - 18.10.2019