Nortel Succession 1000 Installation And Configuration Manual page 94

Signaling server
Table of Contents

Advertisement

Page 94 of 116
Command line interface (CLI) commands
Table 13
Internet Telephone Installer Password commands (Part 2 of 3)
IPL> command
nodeTempPwdSet
"tempPwd", uses, <time>
553-3001-212
Standard 1.00
Description
Sets the temporary Internet Telephone Installer
Password. This password is disabled by default.
The password must be a string 6 to 14 digits in
length. A null password cannot be entered. The
valid tempPwd characters are 0 – 9 * #.
The uses parameter is a numeric value from
0-1000. This parameter specifies the number of
uses for which the temporary password is valid.
The range for the time parameter is 0 – 240 hours,
which is a maximum of 10 days. The time
parameter specifies the duration in hours that the
password is valid.
• If the uses parameter is set to zero, the time
parameter is mandatory. As a result, the
password only expires based on time.
• If the uses parameter is non-zero, the time
parameter is optional.
• If both the uses and time parameters are
entered, the password expires on whichever
comes first, that is, uses is reduced to zero or
the time has expired.
• If both uses and time are entered and both are
set to zero, it is the same as not setting the
temporary password at all.
This command can be entered at any time and the
new parameters overwrite the existing temporary
password's parameters.