Figure 13
Maintenance to Succession Signaling Server connection
Maintenance Terminal
3
Connect a maintenance terminal to the Succession Signaling Server.
a.
Connect a DTE–DTE null modem serial cable (supplied with the
Succession Signaling Server) from the Serial Port on the back of the
Succession Signaling Server to a maintenance terminal. The
connection looks like that shown in Figure 13.
Serial Cable
b.
Set the COM port on the maintenance terminal as follows:
Terminal type: VT100
Speed: 19 200
Data bits: 8
Parity: none
Stop bits: 1
Flow control: none
Note: The Succession Signaling Server is shipped with the Admin/
Serial port set to 19 200 Bit/s. Other available speeds are 9600,
38 400, and 115 200 Bit/s. Once the Succession Signaling Server
software has been installed, the port speed can be changed using the
Tools Menu on the Succession Signaling Server Install Tool. See
Procedure 11 on
4
Configure the maintenance terminal.
The maintenance terminal can be configured any time, except during data
transmission. Do not configure the terminal during data transmission to
avoid data loss.