Site Requirements; Power Requirements; Rack Requirements - Western Digital OpenFlex F3100 User Manual

Hide thumbs Also See for OpenFlex F3100:
Table of Contents

Advertisement

User Guide
• To power off an F3100, browse directly to the F3100. Power off cannot be done from the E3000. To
power back on the F3100, browse to the E3000.
• IPv4 networking only.
• Only one browser session allowed to an individual F3100 device.
• Enforced maximum limits on configuration
◦ 256 Volumes
◦ 256 Hosts
◦ 2048 Queue Pairs
◦ 128 Queue Pairs (1 Admin, 127 IO) per connection
◦ 64 max queue depth per IO Queue Pair
1.6   Site Requirements
1.6.1   Power Requirements
The E3000 is equipped with redundant PSU units. The PSUs are hot-swappable and are located at the rear
of the chassis. The following is a specification summary. Note that the system does not support lowline
voltage.
Table 18: Power Specification
Power Output
Input Voltage
80 PLUS Standard
Connector Type
1.6.2   Rack Requirements
The E3000 is designed to be installed into a rack that meets the EIA-310 standard with a minimum of 1000
mm (39.4 in.) of usable rack space, frame to frame. The vertical rack rails must be set between 718 mm
– 850 mm / 28.26 in. – 33.46 in. to support the enclosure. It requires 3U of rack space, and it should be
installed into the rack at the lowest possible U height to keep the load on the rack balanced.
Table 19: Required Rack Specifications
Rack Depth
Rack Width
Rack Units (U)
Vertical Rack Rail Spacing
Specification
Parameter
Value
1600W
200V - 240V
Platinum
C16
Requirement
1000 mm (39.4 in.) of usable rack space, frame to
frame
450mm (17.72in.) with 465mm (18.31in.) ± 1.5mm
nominal hole spacing. See EIA-310 Rack Standard
3U
718 mm – 850 mm / 28.26 in. – 33.46 in.
1. Overview

1.6 Site Requirements

17