2.4   BMC Module
The OpenFlex E3000 contains a toolless BMC Module that is installed into the center slot at the front of the
Chassis. The BMC Module is accessed using a 1GBe Ethernet management RJ45 port on the rear IO of the
Chassis. The BMC Module enables out of band management (OOBM) using a RESTful interface (via HTTP
or HTTPS). OOBM controls the actions between devices and the BMC Module for powering down, setting
system configurations, and the cooling algorithm for the Fan Modules. The BMC Module may be serviced or
replaced while the enclosure is powered on as long as it is replaced within five minutes of removing it from
the slot. Replacing a BMC module will not effect data flow to devices.
2.4.1   BMC Module Specifications
Table 24: BMC Module Specification
Summary
Specification
Input Current
Input Power
Rated Voltage
Number per Enclosure 1 installed in the center
Part Number
Hot Swappable?
Service window
Dimensions
Weight
2. Components

2.4 BMC Module

Value
2A Maximum
25W
12V +/- 10%
device slot
1EX1917
Yes
5 minutes
W: 55.6 mm x L: 459.12
mm x H: 126.94 mm
W: 2.19 in x L: 18.08 in x
H: 5 in
3.26 lbs. / 1.48 kg
24