Chapter 12
SLA Monitoring.
198
Now that we defined an SLA ping test we need to configure the test. The following
parameters can be configured:
Parameter
test
addr
size
timeout
probePerHop
port
maxTtl
initTtl
createHopEntries
frequency
maxrow
storagetype
trap
type
descr
srcaddr
intf
Description
The name of the traceroute
test to configure.
The destination IP address.
The size of the data portion to
be transmitted in a traceroute
request.
The timeout value, in seconds,
for a traceroute request
The number of times to
reissue a traceroute request
with the same time-to-live
value .
The UDP destination port
number to send to.
The upper limit on the number
of routers through which a
packet can pass.
The initial time-to-live value.
Enables creation of traceroute
hop table.
The number of seconds to wait
before repeating a traceroute
test.
The max number of entries in
the history table.
The storage type of this entry.
The value determines when
and if to generate a
notification.
The implementation method to
be used for the traceroute test.
The descriptive name of the
traceroute test.
Ip source address to be used.
Interface name.
Values
string
string
number{0-20000}
number{1-60}
number{1-10}
number{1-65535}
number{1-255}
number{0-255}
disabled or enabled
number{0-65535}
number{0-100}
volatile or
nonVolatile
[+/-]flag[+/-
flag...]{pathChange
testFailure
testCompletion}
IcmpEcho ro
UdpEcho
quoted string
ip-address
none, loop, ipsec0,
Internet, lan1,
wan1, dmz1, guest1
E-DOC-CTC-20051017-0155 v1.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Speedtouch 620