m .
DATASET 2100 Series Description
Installation
Any connection
of this set to an off premise
application,
an out of plant appiica-
tion, or to any other exposed
plant application
may resuit in a safety hazard,
and/or defective
operation,
and/or equipment
damage.
Table I!%3
installation
of a Standalone
DATASET 2103
'
Step
Action
1.
Install a Standalone
DATASm 2103 by placing it near its associated telephone
set and
data peripheral (its case is designed to lie flat on the desk under a standard telephone).
2.
Complete
Customer Data Entry for the system to allow the Standalone
DATASET 2103 to
operate with the PABX.
3.
4.
Set the eight DIP switches as required for this installation. Refer to Table 15-l.
Connect the telephone
set cord to the jack marked PHONE; connect the modular tele-
phone line cord to the jack marked LINE and to the wall or floor jack which connects to the
PABX main distributing frame (MDF), The connection to the MDF is a four-wire
circuit; the
voice tip and ring (red and green) connect to an ONS or COV line card (depending
on the
type of set being used), and the Dataset Tip and Ring (yellow and black) connect to a Dig-
ital Line Card.
5.
An alternative Trp and Ring wiring arrangement
is: connect the telephone
set through a
two-wire
connection via the MDF to its ONS or COV line card; connect the modular line
cord (data TIP and Ring) to the jack of the Standalone
DATASEr 2103 marked LINE,
through the MDF to its Digital Line Card in the PABX.
6.
Plug the power supply into an ac outlet and its cord into the power socket on the Standa-
lone DATASK
2103. All LEDs should flash 5 times, indicating that the dataset has
passed its self-test.
If this does not happen, the dataset is faulty and must be replaced.
Then the POWER LED comes on, to indicate that the data set is communicating
with the
PABX. if the POWER LED flashes, check the wiring.
7.
Plug the RS-232 interconnecting
cable into the RS-232 connector at the back of the
Standalone
DATASEr 2103 and connect its other end to the peripheral device. When the
RS-232 connector is attached, the DEVICE LED should be on, unless the device is an
auto-answer
device, and defined as such in CDE (usually only destination devices such
as host computers are auto-answer).
if the device is not auto-answer,
and the DEVICE
LED does not come on, make sure the device is powered on, and then use an RS-232
break-out
box to verity that the device provides DTR. if the device does not provide DTR,
select CDE option "RS-232 Force High" for that device.
9109-696126-NA