Mitel SX-200 Practices page 1163

Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

m .
DATASET 1100 Series Description
Installation
1 WARNING
1
Any connection
of this device to an off premise
application,
an out of plant
application,
or to any other exposed
plant application
may result in a safety
hazard, and/or defective
operation,
and/or equipment
damage.
14.9
The following
chart lists the steps required
to install a MiLink Data Module.
Chart 14-I
M/Link
Data Module
installation
instructions
,
Step
Action
Comment
1.
Verii that CDE for the /kfkink Data Module (1101 M) is complete.
2.
Connect an AC adaptor between the AC outlet and MiLink Data
Ail LEDs should flash
Module.
fiie times, if not
replace the ARtink
Data Module.
3.
Connect a SUPERSET 410, SUPERSET 420, or SUPERSfl430
POWER LED stops
telephone set to the MiLkk Data Module at /UiLinkA or /WLhk B
flashing
(another Afj/ink devide can be connected serially to the remaining
/Ktink connection).
4.
Connect FIS-232 cable between the MU&Data
Module and the
Device LED should
peripheral device.
be on, see note 1.
Notes:
1. When
the RS-232
connector
is attached,
the DEVICE
LED should
be on, unless
the devfce
is an
auto-answer
device,
and defined
as such
in CDE (usually
only destination
devices
such
as host
computers
are auto-answer).
If the device
is not auto-answer,
and the DEVICE
LED does
not come
on,
do the following:
*
Make
sure the device
is powered
on.
l
Use
an M-232
break-out
box to verify
that the device
provides
DTR
If the device
does
not provide
DTR,
select
CDE option
DTR always
for that devfce.
2. The POWER
LED should
be on continuously
(except
when
first connected
to AC power),
indicating
connection
to the Digital
Set, If the POWER
LED is flashing,
check
the wiring
between
the MiLink
Data
Module
and the set.
If the POWER
LED continues
to flash,
verify
Customer
Data Entry
(CDE)
for the
device,
9109-096126-NA
Issue 1
Revision 0
126 14-13