Section 2

Pipe Configuration Menu Structure

Application Data
* Default
Use this menu cell to enter the
number of pipe diameters
between the upstream
configuration and the
transducer installation.

PIPE CONFIGURATION OPTION LIST DEFINITIONS

Fully Developed Fully Developed flow, as would be expected for very long straight pipe runs or
1 Elbow
Dbl Elbow +
Dble Elbow -
Valve
Expander
Reducer
Norm Entry
Header Inlet
Intrusions
Pipe Configuration
(Change to Upstream
Piping)
Anomaly Diams
Siemens
Disignate Pipe Shape Near Transducers
Liquid Class
UniMass Table
Temperature Range
Pipe Configuration
Anomaly Diams
Application Data
installation downstream of a flow condition.
Single 90 degree Elbow upstream of transducer installation.
Double out-of-plane Elbows upstream of transducer installation.
Double in-plane Elbows upstream of transducer installation.
To Be Determined.
Pipe expansion upstream of transducer installation.
Pipe reduction upstream of transducer installation.
To Be Determined.
Header or pipe manifold upstream of transducer installation.
To Be Determined.
Fully Developed*
1 Elbow
Dbl Elbow +
Dbl Elbow -
Valve
Expander
Reducer
Norm Entry
Header Inlet
Intrusions
xxxx (numeric entry)
Dual Path [1]
Path 1
Water 20C/68F
Create/Edit Table
-40F to 250F
Fully Developed
1 Elbow
Dbl Elbow +
Dbl Elbow -
Valve
Expander
Reducer
Norm Entry
Header Inlet
Intrusions
2-15
1010PFM-3G
Use this menu cell to select
the pipe configuration that
most accurately represents
the upstream pipe condition.