The Stripchart Setup Menu; Stripchart Setup Menu Structure - Siemens SITRANS F Operating Instructions Manual

Ultrasonic flowmeters portable flowmeter
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Section 2
ENT
Press
and the highlight returns to the [Point #] field.
To enable numeric entry press
ENT
Press
and the cursor moves to the point # 2 [Indicated Rate] field.
Use the numeric keys to type a flow rate for point # 2. The value entered here must
be of a greater magnitude than the value entered for point #1.
ENT
Press
and the cursor moves to the [% Correction] field.
To enable numeric entry press
Use the numeric keys to type the required % correction for point # 2 then press
Repeat this procedure for all required calibration points. After entering the last Flow
Calibration Point press
2.8

THE STRIPCHART SETUP MENU

This menu becomes available after picking a Meter Type and Measurement Channel. Use Stripchart
Setup to select a data category, the type of scaling and the update interval for the on-screen stripchart
display. You can also clear the stripchart screen.
Stripchart Setup
then type [2] (for the second calibration point).
to exit MultiPoint calibration.
THE STRIPCHART SETUP MENU STRUCTURE
Select Data
Data Display
Time Base
Stripchart Clear
2-45
1010PFM-3G
ENT
Vfo
Vfab
Temp
Vs
Valc
Vaer
Data Rate Units
Percent of Span
1 Second
3 seconds
6 seconds
12 seconds
24 seconds
1 minute
3 minutes
6 minutes
12 minutes
24 minutes
1.2 hours
Yes
No