Siemens SITRANS F Operating Instructions Manual page 253

Ultrasonic flowmeters portable flowmeter
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Section 8
Now you are ready to measure the wall thickness. Place the transducer assembly on the prepared
surface, within the applied couplant. Use moderate downward pressure to ensure sonic coupling and
a square contact between the transducer face and the pipe wall. The screen automatically shows the
pipe wall thickness numerically and in graphic form (similar to the example shown below). If you want
to re-check your reading, maintain pressure and then press the
If you want to take subsequent measurements at another location, lift off the transducer from the pipe
wall for about one second to clear the display.
Siemens
When you finish using the Thickness Gauge:
Do not turn off the meter. Press the
Press
twice to return to [Meter Type].
Press
to access the [Meter Type] option list.
Select a flowmeter by pressing
nel Flow].
MENU
key to return to the [Thickness Gauge] menu.
Meter Type
Meter Facilites
to move the cursor to the desired type, for example: [>Dual Chan-
key to reset the display.
CLR
>Thickness Gauge
Dual Channel Flow
Dual Path Flow
Ch 1+2 Flow
Ch 1-2 Flow
8-11