Assigning Io Output Functions; Assigning Vo Output Functions; Assigning Pgen Output Functions; Pulse Output (Pgen Wiring) - Siemens SITRANS F Operating Instructions Manual

Ultrasonic flowmeters portable flowmeter
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Section 2

Assigning Io Output Functions

The Io analog output is a loop-powered (or externally powered), isolated 4-20 mA DC signal that varies
linearly in relation to a selected data function.
To assign a function for the current output:
From [Analog Out Setup], press
Move the cursor to the desired data function by pressing
To store selection press

Assigning Vo Output Functions

The Vo analog output is a 0-10 VDC signal that varies linearly in relation to a selected function.
To assign a function to the voltage output:
To access the [Vo] option list press
Move the cursor to the desired data function by pressing
To store selection press

Assigning Pgen Output Functions

The Pgen analog output is a buffered TTL-compliant pulse rate signal. It varies linearly from 0-5000 Hz
in relation to a selected data function.
To assign a function to the Pgen output:
To access the [Pgen] option list press
Move the cursor to the desired data function by pressing
To store selection press
Installation Drawings 1010P-7 (Sht 2 of 2) and 1010DP-7 (Sht 2 of 2)
PIN#
SIGNAL
10
PGEN1
11
PGEN2
Installation Drawings 1010WP-7 (Sht 2 of 2) and 1010WDP-7 (Sht 2 of 2)
PIN#
SIGNAL
K
PGEN1
L
PGEN2

2.10.2 RELAY SETUP

Use this menu to assign a function to channel relays. The system offers 2 types of relay outputs, Alarm
Relay and Pulse Relay. Alarm Relay outputs operate in "fail-safe" mode. The relay(s) are energized
under normal conditions - an alarm condition causes the relay(s) to de-energize until alarm clears.
Pulse Relay output supports totalizer and batch relay functions. The output pulse width is approxi-
mately 200 ms. The 1010 family of portable instruments use soild state logic levels rather than relays
twice to access the [Io] option list.
ENT
ENT
ENT

PULSE OUTPUT (Pgen Wiring)

Models 1010P & 1010DP
FUNCTION
FREQUENCY OUTPUT 1
FREQUENCY OUTPUT 2
Models 1010WP & 1010WDP
FUNCTION
FREQUENCY OUTPUT 1
FREQUENCY OUTPUT 2
2-54
NOTES
Pulse Freq Output (0-5kHz) 5V TTL CMOS Logic. Use
any available signal gnd for return (Terminal 1, 17 or 26)
NOTES
Pulse Freq Output (0-5kHz) 5V TTL CMOS Logic. Use
any available signal gnd for return (Terminal A, T or c)
1010PFM-3G