5. Once transducer is in place, secure with the transducer clamping screw. Do not overtighten. Ob-
serve the upstream/downstream orientation and connect the transducer cable to the computer's
input jack. If a dual-channel unit, make sure you connect the cable to the input jacks of the correct
channel. Repeat this procedure for the number index transducer.

Installing a 1012T Mounting Track in Direct Mode

Paragraph 2.4 describes the Installation procedures that lead up to the automatic selection of trans-
ducers, mounting mode and spacing method. Shown is a Model 1012T mounting track to accommo-
date size B3 universal transducers. Examine the figure below which shows a typical Pick/Install Xdcr
menu screen. Note the automatic assignment of model numbers for the transducer and mounting
track, plus the designation of number index.
1. Perform all required menu steps up until the point where the flow computer prompts you to press
<ENT> to finish the transducer install routine. Note the reported number index.
You will be inserting an index pin into this hole and the reference hole. Check to ensure that you
have a matched set of transducers. They both should have the same S/N number but marked with
either an "A" or "B" (e.g., 100A and 100B).
2. The direct mount configuration uses two track rails, one for each transducer, installed 180
the pipe. One track rail includes the tension screw while the other has a locating stud to support the
chain (see below and on next page).
Upstream
Upstream
Transducer
Transducer
TOP VIEW
TOP VIEW
INSTALLATION – DIRECT MOUNT 180º OPPOSED WITH MOUNTING TRACK
Siemens
2 Channel
Key [Install] after mounting transducers
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Completed?
Empty Pipe Set
Zero Flow Adjust
Pick/Install Xdcr
Number
Number
Index Pin
Index Pin
Downstream
Downstream
Transducer
Transducer
3-18
[1]
SITE1
1011 Universal
B3
Direct
Minimum
4
Track 1012TP
0.217
No
Channel Not Setup
Channel Not Setup
Transducer Clamping
Transducer Clamping
Screw
Screw
Track Rails
Track Rails
1010PFM-3G
Note selection of track
P/N, Mount Mode and
Number Index.
0
apart on
Chain
Chain Tensioning
Tensioning
Screw
Screw