Section 1
Flexible Transducer Mounting Options
EZ clamp and spacer bars make installing and spacing transducers fast and easy.
Lightweight, rigid transducer mounting frames that can be coupled using spacer bars or in-
stalled separately for stand-alone mounting.
Fixed length mounting tracks (for small transducers).
Mechanical, Electrical, Environmental and Safety Specifications
Weight, 1010P
Dimensions, 1010P
Weight, 1010WP
Dimensions, 1010W P
Power Input
Flowmeter Operating
Temperature Range
Storage Temperature
Range
Operating Altitude
Range
Transport Altitude
Range
Humidity
Service Rating
Safety
7.5 lbs / 3.4 kg
inches: 7.8 W x 10.5 H x 3.5 D
millimeters:197 W x 267 H x 90 D
7.7 lbs / 3.5 kg
inches: 8.50 W x 10.68 H x 6.97 D
millimeters:216 W x 271 H x 177 D
NiCd Battery Operated
Battery Charger: 100-240 VAC +/-10% 50-60 Hz
Battery Charger Temperature Range:
5°C to 35°C (41°F to 95°F)
32°F to 122°F
0°C to 50°C
-40°F to 160°F
-40°C to 71°C
up to 6,563 ft
up to 2,000 m
-2000 ft to 40,000 ft
-609 m to 12,192 m
90% from 32°F to 122°F
90% from 0°C to 50°C
1010P Indoor use; NEMA Type 1, IP40
1010W P Indoor/Outdoor use; IP67
- UL Listed and UL Listed to Canadian Safety Standards,
UL61010-1, File E304857
- Pollution Degree 2
- CAT II