Introduction; About This Field Manual; Conventions; General Installation Menu Notes - Siemens SITRANS F Operating Instructions Manual

Ultrasonic flowmeters portable flowmeter
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Section 1
1.

INTRODUCTION

1.1

ABOUT THIS FIELD MANUAL

This field manual is designed to enable someone with no prior experience to setup and operate the
Siemens SITRANS FUP 1010P Portable Flowmeter. Please visit our web site: www.siemens.com.
There you will find additional documentation for downloading including updated news about the com-
pany and our products.
This field manual focuses on how to setup the flowmeter for dual-channel clamp-on transit-time op-
eration.
Section 1 gives an introduction to the 1010P flowmeter types.
Section 2 explains the 1010P Installation Menu.
Section 3 gives step-by-step transducer installation instructions.
Section 4 shows basic Meter Facilities menu operations.
Section 5 includes System 1010P Application Notes.
Section 6 explains System 1010P operation with Flow Tubes.
Section 7 shows how to use the flowmeter's Reflexor mode.
Section 8 shows how to use the pipe wall Thickness Gauge.

1.1.1 CONVENTIONS

When the text refers to a keypad key, it will be enclosed in "less than" (<) and "greater than" (>)
symbols: e.g., <MENU>, <ENT>, <Up Arrow>, etc. Where a visual of the key is shown; this means
press this key.
When the text refers to a menu or menu cell name, it will be enclosed with square brackets: e.g.,
[Pipe Data], [Channel Enable], etc.
Each menu includes an image of its main screen and a diagram of its structure. The rightmost
column of the structure diagram lists the option list choices of the menu cell, if applicable.
1.1.2

GENERAL INSTALLATION MENU NOTES

If a power failure occurs while you are entering or editing data, the entered data may not be retained
in Active Memory.
Although you can operate the meter immediately after completion of a site setup, we recommend
that you preserve your settings by saving them under a site name. Site data can be saved at any
time before invoking [Recall Site Setup] or [Create/Rename Site] commands. These commands
overwrite all data present in Active Memory.
We do not recommend that you attempt to operate the flowmeter at a new site by recalling and then
editing an existing site setup. Each site must have its own set of transducer install parameters,
even if the data from the recalled site setup is identical. Always issue the [Create/Rename Site] to
begin a new site setup. This will fill all the menu cells with defaults to eliminate the possibility of
retaining unwanted parameters.
The meter allows you to create your own personal site setup defaults. After creating a site setup
and editing default parameters as desired, save the site using the name [FASTSTRT]. The next
time you issue the Create/Name Site command, your custom parameters will become the sys-
tems defaults.
1-1
1010PFM-3G