2.4.9 HOW TO USE [INSTALL COMPLETED?]

Use the [Install Completed?] menu cell to inform the flow computer that you have mounted the trans-
ducers according to the selected mode and spacing requirements and are ready to start operation.
To start the [Install Completed?] routine for an original installation:
Select any transit-time mode (e.g., Clamp-On or Flow Tube) and press the <Right Arrow>.
Press <Down Arrow> and scroll to the [Pick/Install Xdcr] menu cell. Press <Right Arrow>.
Install transducers as required (refer to Section 3 for procedures).
NOTES
Mount the transducers using the selected mode (direct or reflect). Please refer to the trans-
ducer mounting procedures detailed in Section 3.
When using a mounting track or a spacer bar in reflect mode, locate the first transducer at the
Reference Index and the second transducer at the recommended Number Index.
If you are mounting the transducers independently, you must use the recommended distance;
Ltn to space the transducers.
You must use the proper sonic coupling compound. See "Recommended Sonic Coupling
Compounds" in Section 5 for appropriate type and part number.
The pipe must be completely filled with a liquid, which can be either flowing or at zero flow.
After transducers are properly mounted, the flow computer completes its Initial Makeup command and
the [Install Completed?] menu cell appears.
To access the [Install Completed?] option list, press the <Right Arrow>.
Press <Down Arrow> and scroll to the [Install Completed] menu cell and then press <ENT> (un-
less otherwise directed to do so by the Technical Service Department).
Siemens
2 Channel
Key [Install] after mounting transducers
Transducer Model
Transducer Size
Xdcr Mount Mode
Spacing Offset
Number Index
Spacing Method
Ltn Value (in)
Install Completed?
Empty Pipe Set
Zero Flow Adjust
Pick/Install Xdcr
2-21
[1]
SITE1
1011 Universal
B3
Direct
Minimum
4
Track 1012TP
0.217
No
Channel Not Setup
Channel Not Setup
1010PFM-3G