17.1.3 Service Diagnosis

To find out whether the connected encoder or the control interface is defective, you can operate
the encoder with another interface of the control. Use the interface of a functioning axis.
Example:
For fault diagnosis, proceed as follows:
Error in
X-axis
Example machine
parameters
MP 100.x = CZYX (X = 1st axis, Y = 2nd axis, Z = 3rd axis, C = 4th axis)
MP 110.0 = 1 (X-axis at X1 input)
MP 110.1 = 2 (Y-axis at X2 input)
MP 110.2 = 3 (Z-axis at X3 input)
MP 110.3 = 4 (C-axis at X4 input)
MP 115.0 = %0000000000 (all inputs 1 Vpp)
MP 115.1 = %0000000000
MP 115.2 = %0000000000 (all inputs 50 kHz)
Notes and
preliminary
actions
Block diagram
May 2006
Caution
If the scanning head is wet and thus a short circuit is caused, it must not be connected again!
Encoder interfaces are not always short-circuit proof.
On position encoders connected to the CC 424, an exchange is only possible between the
groups X201 to X206 (main drive-control board) and X207 to X214 (auxiliary drive-control
board)!
Note
Always exchange both, the cable and interface assignment by means of machine
parameters!
17 – 281