18.3 Service Diagnosis in PLC mode

18.3.1 TRACE function

The TRACE function allows the monitoring of logic states such as
Markers
Inputs
Outputs
Timers
Counters
as well as the inspection of the contents of
Bytes
Words
Double words
Call
The statement list (STL) of the converted program is displayed. In addition, the contents of the
operand and the accumulator is displayed in HEX or decimal code for every program line. Every
active command of the STL is identified with a "C".
July 2002
The TRACE function is called via the TRACE soft key.
18 – 255