10.2.5 The I/O-FORCE LIST

This diagnosis function is available as of NC software 340490-xx (with programming surface
smarT.NC),
Independently of the currently running PLC program and the status of the hardware, the PLC
inputs and outputs can be set or reset via the I/O-FORCE LIST.
Call
May 2006
DANGER
The I/O-FORCE LIST can overrule safety-relevant monitoring operations in the
PLC program!
This could lead to damage to property or persons.
Make sure that hanging axes are supported!
Consult the machine manufacturer!
Soft key to call the I / O FORCE LIST function
Press this soft key.
Select the inputs and outputs by entering the symbolic or absolute address.
Note
The TABLE, die WATCH LIST oder TRACE IN-CODE can be called before and with the soft
key ADD TO I/O-FORCE LIST inputs and outputs can be added to the I/O-FORCE LIST.
Enter the value 0 or 1 which is to be "forced".
If required, enter a comment.