HEIDENHAIN iTNC 530 Service Manual page 38

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

Entry
INFO
INFO
INFO
INFO
INFO
6 – 38
MAIN PGM
MAIN LINE
MAIN PGMEND
MAIN MACEND
MAIN PATH
PLCEDIT
NCEDIT
RUNPGM
RUNPALET
RUNDATUM
RUNTOOL
RUNTCH
SIMPGM
SIMDATUM
SIMTOOL
RUNBRKPGM Stopping point for block scan
SIMBRKPGM
RUNPRINT
SIMPRINT
MDIPGM
NCFMASK
PLCFMASK
EASYDIR
TCHPATH
SIMTAB
RUNTAB
KINTAB
Description
Started NC program or NC macro
Line number of the started NC program or NC macro
Information about the program end in program run
Byte 0/1
00 01
00 02
00 03
00 04
00 05
00 06
00 07
00 08
In addition, when an NC program is stopped by an
error message, the following information is entered:
NC program, line number, actual position, datum,
datum shifts, tool number
Information about the end of an NC macro
Byte 0/1
00 01
00 02
00 03
00 04
00 05
00 06
00 07
00 08
File for PLC Editor
File for NC Editor
Main program for program run
Pallet table for program run
Datum table for program run
Tool table for program run
Pocket table for program run
Main program for program test
Datum table for program test
Tool table for program test
Stopping point for program test
Path for FN15: PRINT for program run
Path for FN15: PRINT for program test
File for positioning with manual data input
Mask for file management in the NC area
Mask for file management in the PLC area
Paths for standard file management
Datum table for manual measurement
Freely definable table in program test
Freely definable table in program run
Active kinematic table
HEIDENHAIN Service Manual iTNC 530
Emergency stop
Positioning error
Programmed stop
Block end for single block
Geometry error
END PGM, M02
Internal stop key
Data transfer error
(V.24/V.11)
Emergency stop
Positioning error
Programmed stop
Block end for single block
Geometry error
END PGM, M02
Internal stop key
Data transfer error
(V.24/V.11)

Advertisement