Restoring the data
As you could probably not store data from the defective HDR, you must now go back to available
archives (PLC-data, TNC-data) to restore data on the new HDR; if required, the machine
manufacturer can also provide you with PLC or machine data.
26 – 438
Load the backup on the new HDR. --> See "Restore" on page 16 – 266.
Note
Delete the blue check mark for LIES_MP.A in the LST file.
Background:
To each NC software version belongs a LIES_MP.A file which includes the comments on the
current machine parameters (to be found under PLC:\JH\LIES_MP.A). As the replacement
control is normally supplied with the latest NC software version, the LIES_MP.A in your
backup file possibly belongs to an older NC software version. If you have deleted the check
mark in your LST file, the new LIES_MP.A is not overwritten by the old LIES_MP.A.
It is not recommended to protect the LIES_MP.A file on the control as otherwise the file
cannot be updated during an NC software update!