MP
MP3130
MP3140
MP3142
MP3143
MP3210.0-7
MP3240.1
MP3240.2
MP3310
MP3310.0
MP3310.1
MP3411.0-7
May 2006
Function and input
Polarity of the nominal spindle speed
Input:0: M03 positive, M04 negative
1: M03 negative, M04 positive
2: M03 and M04 positive
4: M03 and M04 negative
Counting direction of spindle position encoder output
signals
Input:0: Positive counting direction with
M03
1: Negative counting direction with M03
Line count of the spindle position encoder
Input:100 to 30000 [lines]
Mounting configuration of the spindle position encoder
Input:0: Position encoder directly on the
first spindle
1: Position encoder via transmission (ratio in
MP3450.x and MP3451.x); X30 pin 1: reference
pulse
2: Position encoder via transmission (ratio in
MP3450 and MP3451); X30 pin 1: reference
pulse release
3: Same as input value 1, except that the second
reference pulse is evaluated.
Analog nominal spindle voltage at rated speed for the gear
ranges 1 to 8
Input:0 to 100,000 [V]
Digital spindle motor revolutions at rated speed for the gear
ranges 1 to 8
Input:0 to 100.000 [1000 min
Analog spindle: Minimum nominal value voltage
Input:0 to 9.999 [V]
Digital spindle: Minimum motor speed
Input:0 to 9.999 [1000 min
Analog spindle: Spindle jog voltage for gear shifting
(M4009/M4010)
Input:0 to 9.999 [V]
Digital spindle: Motor speed for gear shifting (M4009/
M4010)
Input:0 to 9.999 [1000 min
Limitation for spindle speed override
Input:0 to 150 [%]
Upper limit
Lower limit
Ramp gradient of the spindle with M03 and M04 for gear
ranges 1 to 8
Input:Analog axes: 0 to 1.999 [V/ms]
Digital axes: 0 to 1.999 [1000 rpm/ms]
Behavior/
SW vers.
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
–1
]
PLC
RUN
–1
]
–1
]
PLC
RUN
PLC
RUN
30 – 497