10.7.4 PLC Outputs

Output signals and
The switching outputs are transistor outputs with current limitation.
addresses
Please note:
Output signals:
Min. output voltage for "1" signal
Addresses:
Address
O0 to O30
O0 to O7
O32 to O62
O64 to O94
O96 to O111
O128 to O158
O160 to O190
Which PLC output is located on which pin of the corresponding connector?
--> See "Connector Designation and Layout" on page 13 – 135!
Supply
See "Power Supply for PLC Outputs" on page 14 – 222
voltage for
PLC outputs
10 – 108
Permissible load: Resistive load (inductive load only with quenching diode parallel to
inductivity)
MC 42x(B), PL 4xxB: Short circuiting of one output is permissible.
No more than one output may be short-circuited at one time.
PLD 16-8: The outputs are short-circuit proof.
Note
The switching outputs need a minimum load of 5 mA.
They conform to EN 61131-2.
DANGER
PLC outputs must neither be connected to a 24-V supply, nor to other PLC outputs with a
difference in potential. Otherwise, the voltage present at the PLC outputs is transmitted to
the power supply. As a result, the PLC outputs that can be switched off may nevertheless
be supplied with this voltage.
This could lead to damage or injury to property or persons!
Number
31
8
31
31
16
31
31
Note
The transmission of output states of handwheels and PLC input/output units (expansion
cards) is performed with HEIDENHAIN serial data transmission busses on the connectors
X23 und X47.
On the X41 and X46 connectors, each output has its own wire.
MC 42x(B), PL 4xxB, PLD 16-8
3 V below supply voltage
Device
PLC outputs directly on the MC, connector X41
Machine operating panel (MC, X46)
First PLC input/output unit (MC, X47)
Second PLC input/output unit
Handwheels HR 410, HR 332 and handwheel adapter
HRA 110 (MC, X23)
Third PLC input/output unit
Fourth PLC input/output unit
HEIDENHAIN Service Manual iTNC 530