15.6 File Management PLC Partition (PLC:\)

Calling the PLC
partition
The directory structure is displayed on the left.
The associated files are listed on the right.
May 2006
Press the following key combination to call the PLC partition:
Select the Programming and Editing operating mode
Call window for code number
After the code number has been entered, the PLC main menu is displayed.
Note
If the dialog READONLY appears on the left side of the screen, the machine manufacturer
has protected the PLC partition with his own code number. As a result, the OEM.SYS
system file cannot be called again. All other PLC files can still be read but cannot be edited
any more.
Call Program Management
With the UP and DOWN keys, the corresponding subdirectories or files can be
selected. The selected directory or the selected file are indicated in the header.
With the +/- key you can open and close subdirectories.
Use the LEFT and RIGHT arrow keys to move between the directory and file
side of the screen.
Enter and confirm code number
15 – 241