HEIDENHAIN iTNC 530 Service Manual page 94

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

Writing back to
RAM
10 – 94
Enter the PLC code number --> see "Code Numbers" on page 3 – 13
Shift the soft-key row.
Call the TABLE function.
Shift the soft-key row.
Enter the target directory and the file name under which the states of the
PLC markers and words are stored on the hard disk.
The default setting offered by the iTNC is PLC:\PLCMEM.A.
The stored states of the PLC markers and words are restored in the RAM.
Exit PLC operating mode.