30.4.9 3-D Touch Probe

MP
MP6010
MP6120
MP6130
MP6140
MP6150
MP6160
MP6161
MP6162
MP6163
MP6165
30 – 504
Function and input
Selection of the touch probe
Input:0: Touch probe with cable transmis-
sion (TS 120, TS 220)
1: Touch probe with infrared transmission (TS
632)
2: Touch probe with infrared transmission (TS
440, TS 640)
Probing feed rate
Input:1 to 3000 [mm/min]
Maximum measuring range
Input:0.001 to 99,999.9999 [mm]
Setup clearance over measuring point
Input:0.001 to 99,999.9999 [mm]
Rapid traverse in probing cycle
Input:10 to 20,000 [mm/min]
M function for probing from opposite directions
Input:–1: Spindle orientation directly by
NC
0: Function inactive
1 to 999: Number of the M function for spindle
orientation through PLC
M function for orienting the touch probe before every
measuring process
Input:–1: Spindle orientation directly by
the NC
0: Function inactive
1 to 999: Number of the M function
Orientation angle
Input:0 to 359.9999 [°]
Minimum difference between the current spindle angle and
MP6162 before executing an oriented spindle stop
Input:0 to 3.0000 [°]
Orient the probe before approaching with Cycle 0 or 1, or
with manual probing
Input:0: Probe is not oriented before each
probing
1: Probe is oriented and always deflected in the
same direction
Behavior/
SW vers.
PLC
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
CN123