Now back up the original network settings of the iTNC 530:
With the dual-processor control, write down the original network settings.
With the single-processor control, these DEFINE NET settings are filed in a certain file ...
Now adapt the original network settings of the iTNC 530:
With the dual-processor control, adapt the original network settings under Windows.
With the single-processor control ...
The following display appears ...
May 2006
Call the PLC partition (PLC code number) and subsequently the program manager.
Enter the folder NET.
For this purpose copy the file ip4-n00 (in PLC:\NET) as ip4-n00.txt (or similar) or write
down the information in this file.
Note
If there is a P in the status column of the file ip4.n00, it is protected against editing. This
protection can be cancelled: Press the soft keys AUX. FUNCTIONS --> UNPROTECT.
The P in the status column disappears and the network settings can be changed.
Enter the code number NET123 on the control and press the soft key DEFINE NET.
Press the soft key INSERT LINE (if available, depending on the NC software version).(You can
then enter new settings without overwriting existing settings.)
Adapt the IP address of the control to the IP address of your laptop.
Note
We recommend to use the IP address of the laptop and to increase or decrease the last
place by one.
Example:
Address of the laptops160.1.11.227
Address of the iTNC160.1.11.228 or 160.1.11.226
16 – 251