MP
MP7683
May 2006
Function and input
Executing pallet tables and NC programs
Format:%xxxxx
Input:Bit 0 – No function
Bit 1 – Program Run, Full Sequence
mode
0: During the start, a complete NC program is
run.
1: At the start all NC programs are executed up
to next pallet.
Bit 2 – Program Run, Full Sequence
mode
0: As defined in bit 1
1: All NC programs and pallets up to the end of
the table are executed.
Bit 3 – When the end of the table is reached, the
process begins again with the first line.
0: Function is not in effect
1: Function is effective (bit 2=1)
Bit 4 – Editing the active pallet table
0: Active pallet table cannot be edited.
1: In the Program Run, Full Sequence
and Program
modes, the current pallet table can be
edited.
Bit 5 – AUTOSTART soft key
0: Do not display soft key
1: Display soft key
Bit 6 – Display of pallet table and NC program
0: Both simultaneously in a split screen
1: Pallet table or NC program individually
Bit 7 – AUTOSTART function
0: AUTOSTART function by NC
1: AUTOSTART function by PLC
Behavior/
SW vers.
PLC
RUN
Run,
Single
Block
30 – 535