Step 1540-27 - IBM RS/6000 44P 270 Service Manual

Rs/6000 44p series
Hide thumbs Also See for RS/6000 44P 270:
Table of Contents

Advertisement

Step 1540-27

The last FRU installed or one of its attached devices is probably defective.
1. Turn off the power and remove the power cable from the power outlet.
2. Starting with the last installed adapter, disconnect one attached device and cable.
3. Plug in the power cable (and wait for OK on the operator panel display).
4. Turn on the power.
5. If the Console Selection screen displays, choose the system console.
6. Enter the appropriate password if you are prompted to do so.
Does the system stop with code 4B2xxx00 or 4B2xxx10 displayed on the operator
panel?
NO
YES
70
Service Guide
The last device or cable that you disconnected is defective.
Exchange the defective device or cable.
Go to "MAP 410: Repair Checkout" in the RS/6000 and Eserver pSeries
Diagnostics Information for Multiple Bus Systems.
Repeat this step until the defective device or cable is identified or all the
devices and cables have been disconnected.
If all the devices and cables have been removed, then one of the FRUs
remaining in the system is defective.
To test each FRU, exchange the FRUs in the following order:
1. Adapter (last one installed)
2. I/O board (see note 4 on page 27).
If the symptom did not change and all the FRUs have been exchanged, go to
"Step 1540-2" on page 52.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7044-270